Nexus Integration with Prometheusπ
Nexus Package Upgradesπ
If you are upgrading from versions prior to 42.0.0-bb.4
there are considerations to make for upgrade paths and inclusion of new values. In 42.0.0-bb.4
this package was updated to change the user for metrics collection basicAuth
from admin
to a metrics
user. This was in an effort to reduce the permissions of the user with credentials stored in kubernetes.
Big Bang Defaultπ
By default, Installation of Nexus Repository Manager through the Big Bang chart will result in .Values.monitoring.serviceMonitor.createMetricsUser
being set to true
. If this is a new installation of Nexus through Big Bang, it will run the job to establish the metrics user in Nexus required for the service monitor authentication. It is recommended that after initial installation, that .Values.monitoring.serviceMonitor.createMetricsUser
and .Values.secret.enabled
be set to false
. This will prevent the job from running again, as well as remove the Nexus admin credentials from kubernetes.
If you are performing an upgrade of Big Bang with Nexus currently deployed, This job will likely fail until you add an override to nexus through .Values.custom_admin_password
set to your current admin password. The job should then function as intended and then the recommendations for setting .Values.monitoring.serviceMonitor.createMetricsUser
and .Values.secret.enabled
be set to false
still apply.
Updating values in Big Bang after installation would look like:
addons:
nexus:
enabled: true
values:
secret:
enabled: false
monitoring:
serviceMonitor:
createMetricsUser: false
Package Installationπ
The recommended process for new installations of this package include:
- set
.Values.monitoring.serviceMonitor.createMetricsUser
totrue
- set
.Values.secret.enabled
totrue
- reconcile the package and ensure the target in prometheus for nexus is
UP
- set
.Values.monitoring.serviceMonitor.createMetricsUser
tofalse
- set
.Values.secret.enabled
tofalse
- This will remove the admin credentials secret from persisting in the cluster.
Package Upgradeπ
The recommended process for upgrading an existing installation include:
- set
.Values.monitoring.serviceMonitor.createMetricsUser
totrue
- set
.Values.secret.enabled
totrue
- set
.Values.custom_admin_password
to your current admin password - set
.Values.monitoring.serviceMonitor.createMetricsUser
tofalse
- set
.Values.secret.enabled
tofalse